Mô tả
Hãng sản xuất: NirecoLoại: Cảm biến chình biên
Xuất xứ Nhật bản
Hãy liên hệ với chúng tôi để được hỗ trợ tốt nhất !
Nguyễn Hoàng Tài
Tel: 0915 031 817 or 01686 530 609
Email: sale10@tmpvietnam.com
hoangtai.tmpvietnam@gmail.com
Overview
The TC920V Tension Controller can be used with a wide range of web manufacturing and treatment processes to automatically control the tension of a moving web to a constant value. Digital calculation allows a wider range of functions than previous products, but the controller can still be operated in the intuitive style of an analog device. This controller combines stable and precise tension control with excellent cost performance.
Feature
- Control knobs for frequently-used operations
Control knobs are used for tension settings and manual settings to give a familiar feel. - Clear display
A four-digit LED display is used for quick and easy checking and an LCD display for more extensive information. - Simple zero and span adjustment on installation
Automatic adjustment functions make adjustment a simple process. Tension control is conducted with the start contact only. The system automatically outputs pre-output on startup, and slack-prevention output on stop. - Excellent responsivity and stability
Proportional and integral action are augmented by our renowned fixed loop gain calculation. - Connection with a wide range of tension sensors
Can be connected to the following wide range of Nireco sensors: MB, MG, MC, CD, MJ, CJ, TSA, and intrinsically safe TSA sensors - Free choice of actuators
Electromagnetic brakes and clutches, pneumatic brakes and clutches and torque motors can be used. - Compatible with automatic paper splicing
The new/old spindle switching signal produces paper splicing preset output for paper splicing with little variability. - Diameter measurement function
An encoder or other suitable sensor can be connected to measure roll diameter.
Function
Loop Gain Correction Circuit Provides Excellent Responsiveness and Stability
- Tension Signal Converter
Digitally display the sum or product of the No. 1 and No. 2 tension sensor tensions. - Control Calculator
A control calculator compares the tension signal from the tension display with the target tension, and reduces any variation. Additionally, the ever-popular constant loop-gain control delivers superb control stability and responsiveness, regardless of coil diameter. - Output Amp
When the magnetic brake/clutch on the final control element is used, the power of the control signal is increased, and output at 0 to 24 V (4A). When the air brake/clutch is used, 4 to 20 mA is output to the electro-pneumatic converter. When a torque motor is used, a 0 to 10 V (2mA) voltage signal is output to the motor driver.
Specifications
Power supply voltage | 100 to 240V AC 50/60Hz | |||
---|---|---|---|---|
Power consumption | 300VA (Entry cuurent 60Atyp (20ms)) | |||
Current capacity | 1.5A (200V) | |||
Mass | 6kg | |||
Environment | Operating ambient temperature | 0 to +50°C | ||
Operating ambient humidity | 35 to 85%RH (no condensation) | |||
Vibration resistance | 3.5mm, 1G, 3 to 150Hz, 3 directions (for one hour) | |||
Power source noise | 2kV, normal mode, pulse width of common mode 50 nS, 1 uS (depends on the noise simulator) |
|||
Operating ambient atmosphere | Place free from water droplets, inflammable gas, corrosive gas, corrosive gas, and dust | |||
Rated tension | 10~10000N | |||
Tension sensors that can be connected to the TC920V | MB, MG, MC, CD, MJ, CJ, TSA, and intrinsically safe TSA tension sensors. | |||
Output | Output for measurement | Tension value voltage output (0 to 10VFS (1 mA or less)) Current output for tension value meter (0 to 1mA/FS) |
||
External setting power supply | 0 to 10V (1 mA or less), 4 to 20mA (470Ω or less) 0 to 24V (4A or less) |
|||
Power supply for external setting | Power supply for external setting | |||
Contact output | Zero tension output Minimum diameter output Automatic control output |
Number of outputs, 3 (DC30V 0.2A, AC200V 0.2A) |
||
Input | Sensor input | •MG tension sensor •MB tension sensor •MC tension sensor •CD tension sensor •MJ tension sensor •CJ tension sensor •TSA tension sensor |
||
Analog input | •External tension setting •External manual tension setting |
A number of inputs, 2 (0 to 5V, input impedance 100kΩ) | ||
•Analog diameter (for Taper and Start level) •New spindle deameter (for splicer) •External start level setting •External taper rate |
A number of inputs, 4 (0 to 10V, input impedance 100kΩ) | |||
Contact input | •Automatic •Memory reset •Accelerate/decelerate •Splice •Output on •Emergency stop, external automatic / manual or accelerate •Diameter calculation reset •Diameter calculation hold |
A number of inputs, 8 (12V DC, 12mA) | ||
Pulse generator Gate generator | Detection for speed and diameter | 12V DC |
Người gửi / điện thoại
Mọi thông tin chi tiết vui lòng liên hệ theo thông tin bên dưới để được tư vấn rõ hơn:
Mr. Tài
Hotline: 01686.530.609 - 0915.031.817
mail: sale10@tmpvietnam.com - hoangtai.tmpvietnam@gmail.com
Địa chỉ: 602/41E, Điện Biên Phủ, P22, Quận Bình Thạnh, Tp HCM